Warping machine to remove static electricity

Release time:2021-12-28 Views:555Second

Warping machine to remove static electricity

Static Hazards:

Static electricity is generated when the fabric passes through the ceramic eyelets and combs. The electrostatic charge generated on the individual fibers will cause the fibers to attract or repel each other, and when the fibers pass through the eyelets and combs again, the fibers can easily break. In addition, this condition affects the appearance of the fibers on the weaving shaft. These types of issues can result in costly machine downtime and lead to product scrap.


solution:

Air-sourced ion bars are installed in front of the problem area. The flow of ionized air removes static electricity from the fibers, increasing yield, improving quality, and reducing reject rates. Use KP506A air source type static elimination rod.